Auger Disconnected | Damaged or disconnected auger motor. | Ensure the auger motor is connected to the controller. | https://www.traegergrills.com/support/wiring |
Auger Overcurrent | Auger motor is jammed or malfunctioning. | See related page. | https://www.traegergrills.com/support/auger-overcurrent |
Bad Probe | The meat probe is bad. | Replace the meat probe. | https://www.traegergrills.com/parts/replacement-meat-probes |
Box Shield Open | The hopper lid is open. | Close the hopper lid. | N/A |
Cold Weather Start Up | The grill is notifying you the external temperature is lower than average and start up may take longer. | No troubleshooting needed. This is just a warning that the grill may take longer to ignite. | N/A |
Cook Cycle Complete | A step in your guided grill cook has completed. | N/A | https://www.traegergrills.com/support/app-make-now |
Cook Cycle Next Step | The guided cook has continues to the next step. | N/A | https://www.traegergrills.com/support/app-make-now |
Cook Cycle Started | The guided cook has started. | N/A | https://www.traegergrills.com/support/app-make-now |
Customer Cook Needs Probe | The grill senses the meat probe has not been inserted into the food. | Insert the meat probe or unplug it from grill controller. | https://www.traegergrills.com/support/insert-meat-probe |
Failed to Ignite | Grill failed to ignite. | See related article | https://www.traegergrills.com/support/grill-not-igniting-dc |
Fan Disconnected | The induction fan is damaged or disconnected from the controller. | Ensure the fan is connected correctly to the controller. | https://www.traegergrills.com/support/wiring |
Flame Out Recovery | Grill temperature has significantly decrease. Grill is attempting to re-ignite. | Ensure your grill has pellets. | N/A |
High Temp Error | Temp remained above 550°F/288°C for 45 seconds. | See article. | https://www.traegergrills.com/support/grill-fires https://www.traegergrills.com/support/running-too-hot-dc |
Ignitor Disconnected | Hotrod is damaged or disconnected from the controller. | Ensure the hotrod is connected correctly to the controller. | https://www.traegergrills.com/support/wiring |
Insert Meat Probe | The grill senses the meat probe has not been inserted into the food. | Insert the meat probe or unplug it from grill controller. | https://www.traegergrills.com/support/insert-meat-probe |
Lid Open | The grill lid is open. | Ensure lid is securely closed. If there is a lid gap, see related article. | https://www.traegergrills.com/support/lid-gap |
Low Ambient Temp | Received after 30 seconds of starting the grill when the ambient temp below 20°F/-6°C. | No troubleshooting needed. This is just a warning that the grill may take longer to ignite. | N/A |
Low Temp Error | Temp remained under 120°F/49°C for 10 minutes. | See related article. | https://www.traegergrills.com/support/low-temp-error |
Pellet Level Low | Pellet level in the hopper is running low. | Add pellets to the hopper. | https://www.traegergrills.com/support/pellet-sensor |
Pre-heating Finished | The grill is within 15°F/8°C of the goal temperature or has been pre-heating for 10 minutes. | N/A | N/A |
Probe Fell Out | Meat probe temp reached above 220°F/104°C for longer than 30 seconds. | Ensure the meat probe is inserted into the meat properly. If the problem continues, replace the meat probe. | https://www.traegergrills.com/support/meat-probes |
Probe Temp Reached | Meat probe has reached goal temperature. | N/A | https://www.traegergrills.com/support/meat-probes |
Shutdown Finished | The grill's shutdown cycle is completed. | N/A | https://www.traegergrills.com/support/shutdown-cycle |
Slow Ignition Warning | Grill temp has not significantly increased in 15 minutes. | The grill is notifying you it is taking longer to ignite. An overshoot of the set temperature before leveling out is normal. Ensure grill has enough pellets. | N/A |
Temp Sensor Disconnected | The grill's temperature reader (thermocouple) has been disconnect from the controller. | Ensure the thermocouple is connected correctly to the controller. | https://www.traegergrills.com/support/wiring |
Time to Clean Grill | Based on your logged cooked time, it is time to clean your grill. | Clean grill before your next cook to ensure proper grill function. | https://www.traegergrills.com/support/grill-maintenance |
Time to Clean Grease Trap | Based on your logged cooked time, it is time to clean your grill trap. | Clean out the grease trap before your next cook. This is very important. Extra grease can cause grill fires. | https://www.traegergrills.com/support/grill-maintenance |
Timer Complete | The timer set by the user or by a recipe selection is completed. | Set the table and get to eating! | N/A |
Clear Notifications is a useful controller function that clears non-critical notifications. You may want to use this if you find the controller is stuck on a notification like, "Clean grill."